Estudio comparativo entre fijador externo versus placa volar de estabilidad angular en las fracturas de radio distal.

Autores/as

Palabras clave:

Fractura, Radio Distal, Fijador Externo, Placa Volar, Estabilidad Angular, Fracture, Distal Radius, External Fixator, Volar Plate, Angular Stability

Resumen

Las fracturas del radio distal están entre las patologías más comunes en el área de la emergencia, actualmente los tratamientos más utilizados son la fijación con alambres de Kirschner y fijador externo (AKFE), o la osteosíntesis con placas volares de estabilidad angular (PVEA), realizamos un estudio comparativo de los resultados a corto plazo entre ambos métodos. Se realizó un estudio transversal, retrospectivo y descriptivo desde el 2005 al 2019, donde se revisaron las historias de los pacientes con fracturas de radio distal tratados con AKFE o PVEA, evaluando el alta después de la medición de la amplitud de movimiento articular funcional. Se incluyeron 68 pacientes, 47(69,11%) pacientes tratados con PVEA y 21(30,88%) con AKFE, la edad promedio fue de 53,07 años, la causa más común fue la caída de su altura en 60,29% casos, el alta médica por mejoría se realizó a las 15,95 semanas para AKFE y a las 9,86 semanas para PVEA (<0.05). La osteosíntesis con PVEA evidenció un menor tiempo de recuperación de la amplitud de movimiento articular con respecto a los pacientes tratados con AKFE.

Fractures of the distal radius are among the most common pathologies in the emergency area, currently the treatment more frequently used are fixation with Kirschner wires and external fixator (KWEF), or osteosynthesis with angular stability volar plates (FAVP), we carried out a comparative study of the short-term results between both methods. This is a cross-sectional, retrospective and descriptive study from 2005 to 2019, where the histories of patients with distal radius fractures treated with KWEF or FAVP revised, evaluated, evaluating at discharge after functional joint range of motion was measured.68 patients were evaluated, 47 patients treated with FAVP and 21 with KWEF, average age of 53.07 years, the most common cause was the fall from his height with 60.29%, the medical discharge was made at 15,95 weeks for KWEF and 9,86 weeks for FAVP; with a t student<0.05 between them. Osteosynthesis with FAVP evidenced a shorter recovery time for joint range of motion compared to patients treated with KWEF.

Descargas

Los datos de descargas todavía no están disponibles.

Descargas

Publicado

2023-09-28

Cómo citar

Miot Boncy, D. (2023). Estudio comparativo entre fijador externo versus placa volar de estabilidad angular en las fracturas de radio distal. Revista Venezolana De Cirugía Ortopédica Y Traumatología, 53(2), 58–64. Recuperado a partir de http://saber.ucv.ve/ojs/index.php/rev_vcot/article/view/26809

Número

Sección

Artículo original