Por favor, use este identificador para citar o enlazar este ítem:
https://saber.ucv.ve/jspui/handle/10872/30797| Título : | Dispositivos Intrauterinos Colocados en el Posparto Inmediato: Evolución Durante el Puerperio |
| Autor : | Peña Carrizalez, Laura Isabel Pérez Hernández, Karelys Alejandra |
| Palabras clave : | Dispositivo Intrauterino Posparto Inmediato Puerperio Planificación Familiar Posparto Obstetricia y Ginecología Facultad de Medicina-UCV Trabajo Especial de Grado Intrauterine Device Immediate Postpartum Period Postpartum Period Postpartum Family Planning |
| Fecha de publicación : | dic-2019 |
| Resumen : | Objetivo: Describir la evolución durante el puerperio en pacientes portadoras de dispositivos intrauterinos insertados en el posparto inmediato, en el Servicio de Sala de Partos de la Maternidad Concepción Palacios, entre enero y junio 2019. Métodos: Estudio prospectivo, descriptivo y longitudinal, que incluyó 183 mujeres, a quienes, previa firma del consentimiento informado, se les insertó un dispositivo intrauterino en periodo posparto inmediato (primeros 10 minutos postalumbramiento). Se practicó ecografía inmediata, a los 7 y 30 días: se midió la distancia entre el fondo uterino y el dispositivo y se interrogó a la paciente con respecto a las posibles complicaciones. Resultados: No hubo perforaciones ni reacciones vaso-vagales durante la inserción. El dolor fue referido como leve por 79,8 % de las pacientes. La frecuencia de expulsión al día 30 fue de 3,3 %, hubo 4 descensos (2,2 %). A la hora de la inserción, la distancia fondo-dispositivo intrauterino era menor a 20 mm en 6 casos (3,3 %) pero al día 30 se encontró esta distancia en 173 pacientes (97,7 %). La tasa de continuación fue de 94,5 %. La tasa de continuación fue independiente de la edad (p=0,532), el estado civil (p=0,644), y el nivel educativo (p=0,750), pero fue mayor en multíparas (66,5 %) (p=0,045). No hubo efectos adversos durante el seguimiento. Conclusiones: La inserción del dispositivo intrauterino en el periodo posalumbramiento es segura y bien tolerada. La tasa de expulsión es baja y la continuación elevada. No se identificaron factores asociados a la expulsión. Objective: To describe the evolution during the postpartum in patients carrying intrauterine devices inserted in the immediate postpartum, in the Service of Birthroom of the Maternity Concepción Palacios, between January and June 2019. Methods: Prospective, descriptive and longitudinal study, which included 183 women, who, after signing the informed consent, were inserted an intrauterine device in immediate postpartum period (first 10 minutes post-placental expultion). An ultrasound was performed at 1 hour, 7 and 30 days after the insertion: the distance between the uterine bottom and the device was measured and the patient was questioned for possible complications. Results: There were no perforations or vaso-vagal reactions during insertion. The pain was referred to as mild by 79.8% of patients. The frequency of expulsion per day 30 was 3.3 %, there were 4 decreases (2.2%). At the time of insertion, the bottom-intrauterine device distance was less than 20 mm in 6 cases (3.3%) but, at day 30 this distance was found in 173 patients (97.7%). The continuation rate was 94.5%. The continuation rate was independent of age (p-0.532), marital status (p-0.644), and educational level (p-0.750), but was higher in multiparous (66.5%) (p-0.045). There were no side effects during follow-up. Conclusions: Insertion of the intrauterine device in the posplacental expultion period is safe and well tolerated. The ejection rate is low and the continuation is high. No factors associated with expulsion were identified |
| Descripción : | Universidad Central de Venezuela, Facultad de Medicina, Coordinación de Estudios de Postgrado; Maternidad Concepción Palacios.Trabajo Especial de Grado que se Presenta para Optar al Título de Especialista en Obstetricia y Ginecología |
| URI : | https://saber.ucv.ve/jspui/handle/10872/30797 |
| Aparece en las colecciones: | Otras (Especializaciones) |
Ficheros en este ítem:
| Fichero | Descripción | Tamaño | Formato | |
|---|---|---|---|---|
| Peña L, Pérez K_finalpublicación.pdf | 1.59 MB | Adobe PDF | Visualizar/Abrir |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.