Por favor, use este identificador para citar o enlazar este ítem:
https://saber.ucv.ve/jspui/handle/10872/30523| Título : | Cirugía sin Huella: Puerto con Guante Versus Dispositivo Laparoscópico de Incisión Único en Esterilización Quirúrgica |
| Autor : | Villegas Padrón, Eduardo José |
| Palabras clave : | Puerto con Guante Dispositivo Laparoscópico de Incisión Único Esterilización Quirúrgica Eficacia Costo Port With Glove Laparoscopic Device of Single Incision Surgical Sterilization Efficiency Cost Trabajo Especial de Grado Facultad de medicina Cirugía General |
| Fecha de publicación : | mar-2018 |
| Resumen : | Objetivo: Comparar la eficacia del puerto con guante (Glove port) versus el dispositivo laparoscópico de incisión único (SILS), en la esterilización quirúrgica. Métodos: estudio de cohorte (cuasi-experimental) prospectivo y unicéntrico, con una muestra de 60 pacientes aleatoriazados en dos grupos equitativos, programados electivamente para esterilización quirúrgica, evaluándose los costos que acarrean la realización de la técnica con el uso de ambos dispositivos, en el Hospital General del Oeste “Dr. José Gregorio Hernández”, en Caracas - Venezuela, durante el periodo enero- junio de 2014. Resultados: El tiempo de ensamblado fue 3,5 minutos en el Glove Ports y 2,9 minutos en SILS. El tiempo quirúrgico fue 18 minutos, y de 20 minutos; respectivamente. En relación al costo se demostró que el uso de treinta dispositivos Glove Ports representó un valor de 112,2$, mientras que el uso de tres SILS fue de 600$. Conclusión: El puerto con guante (Glove port) en la esterilización quirúrgica es eficaz debido a que el costo del Glove Ports fue 5,34 veces inferior en comparación al dispositivo SILS, sin diferencias estadísticas en cuanto a las comorbilidades inherentes a la técnica. Objective: To compare the efficacy of the glove port versus the single incision laparoscopic device (SILS) in surgical sterilization. Methods: prospective and unicentric cohort (quasi-experimental) study, with a sample of 60 randomized patients in two equitative groups, electively programmed for surgical sterilization, evaluating the costs involved in performing the technique with the use of both devices, in the Hospital General del Oeste "Dr. José Gregorio Hernández", in Caracas - Venezuela, during the period January-June 2014. Results: The assembly time was 3.5 minutes in the Glove Ports group and 2.9 minutes in SILS¨s, while the surgical time was 18 minutes and 20 minutes, respective. In relation to the cost, the use of thirty devices Glove Ports demonstrated a value of 112,2 $, whereas the use of three SILS cost 600 $. Conclusion: The Glove Port in surgical sterilization is effective because the cost was 5.34 times lower in comparison to the SILS device, with no statistical differences regarding the inherent comorbidities of the technique |
| Descripción : | Universidad Central de Venezuela, Facultad de Medicina, Coordinación de Estudios de Postgrado, Hospital General del Oeste. Trabajo Especial de Grado que se Presenta para Optar al título de Especialista en Cirugía General |
| URI : | https://saber.ucv.ve/jspui/handle/10872/30523 |
| Aparece en las colecciones: | Otras (Especializaciones) |
Ficheros en este ítem:
| Fichero | Descripción | Tamaño | Formato | |
|---|---|---|---|---|
| eduardovillegas_finalpublicacion.pdf | 485.37 kB | Adobe PDF | Visualizar/Abrir | |
| 0048_260910115236_002.pdf | 426.03 kB | Adobe PDF | Visualizar/Abrir | |
| 0050_260910115332_002.pdf | 237.27 kB | Adobe PDF | Visualizar/Abrir | |
| 0049_260910115316_002.pdf | 360.78 kB | Adobe PDF | Visualizar/Abrir |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.