Please use this identifier to cite or link to this item: https://saber.ucv.ve/jspui/handle/10872/3926
Full metadata record
DC FieldValueLanguage
dc.contributor.authorShannon, Mark A.-
dc.contributor.authorMao, Xianglei L-
dc.contributor.authorFernández, Alberto-
dc.contributor.authorChan, Wing·Tat-
dc.contributor.authorRusso, Richard E.-
dc.date.accessioned2013-07-17T21:51:52Z-
dc.date.available2013-07-17T21:51:52Z-
dc.date.issued1995-
dc.identifier.issn0003-2700-
dc.identifier.urihttp://hdl.handle.net/10872/3926-
dc.description.abstractFor laser ablation solid sampling, the quantity of material ablated (removed) influences the sensitivi1y of chemical analysis. The mass removal rate depends strongly on the laser power density, which is the main controDable parameter for a given material and wavelength parameter using laser solid samplingfor inductively coupled plasma atomic emission spectroscopy (ICP-AES). For a wide variety of materials, a decrease in the rate of change, or roll-off, in mass removed is observed with increasing incident laser power density. The roll-off results from a change in the efticiency of material removed by the laser beam, primarily due to shielding of the target from the incident laser energy by a laser-vapor plume interaction. Several analytical technologies were employed to studythe quantity of mass removed versus laser power density. Data for mass ablation behavior versus laser power density are reported using ICP-AES, atomic emission from a Iaser-induced plasma near the sample surface, acoustic stress power in the target, and measurements of crater volumes •. This research demonstrates that the change in ICP-AES intensity with laser power density is dueto changes in the mass removal. The roll-off in mass ablation is not due to a change in particle size distn"bution of the ablated species, fractionation of the sample, or a change in transport efticiency to the ICP torch. Accurate tracking of the ICP-AES with the laser ablation process justifies the use of internal and external standardization.es_VE
dc.language.isoen_USes_VE
dc.publisherReprinted from Analytical Chemistryes_VE
dc.relation.ispartofseries;67-
dc.subjectLaser Ablationes_VE
dc.subjectMass Removales_VE
dc.subjectPower Densityes_VE
dc.subjectduring Solid Samplinges_VE
dc.subjectPlasmaes_VE
dc.titleLaser Ablation Mass Removal versus lncident Power Density during Solid Sampling for lnductively Coupled Plasma Atomic Emission Spectroscopyes_VE
dc.typeArticlees_VE
Appears in Collections:Artículos Publicados



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.