Espacio reservado para banners y logos institucionales

SABER UCV >  1) Investigación >  Artículos Publicados > 

> Laser Ablation Mass Removal versus lncident Power Density during Solid Sampling for lnductively Coupled Plasma Atomic Emission Spectroscopy
Please use this identifier to cite or link to this item: https://saber.ucv.ve/handle/10872/3926

Title: Laser Ablation Mass Removal versus lncident Power Density during Solid Sampling for lnductively Coupled Plasma Atomic Emission Spectroscopy
Authors: Shannon, Mark A.
Mao, Xianglei L
Fernández, Alberto
Chan, Wing·Tat
Russo, Richard E.
Keywords: Laser Ablation
Mass Removal
Power Density
during Solid Sampling
Plasma
Issue Date: 1995
Publisher: Reprinted from Analytical Chemistry
Series/Report no.: ;67
Abstract: For laser ablation solid sampling, the quantity of material ablated (removed) influences the sensitivi1y of chemical analysis. The mass removal rate depends strongly on the laser power density, which is the main controDable parameter for a given material and wavelength parameter using laser solid samplingfor inductively coupled plasma atomic emission spectroscopy (ICP-AES). For a wide variety of materials, a decrease in the rate of change, or roll-off, in mass removed is observed with increasing incident laser power density. The roll-off results from a change in the efticiency of material removed by the laser beam, primarily due to shielding of the target from the incident laser energy by a laser-vapor plume interaction. Several analytical technologies were employed to studythe quantity of mass removed versus laser power density. Data for mass ablation behavior versus laser power density are reported using ICP-AES, atomic emission from a Iaser-induced plasma near the sample surface, acoustic stress power in the target, and measurements of crater volumes •. This research demonstrates that the change in ICP-AES intensity with laser power density is dueto changes in the mass removal. The roll-off in mass ablation is not due to a change in particle size distn"bution of the ablated species, fractionation of the sample, or a change in transport efticiency to the ICP torch. Accurate tracking of the ICP-AES with the laser ablation process justifies the use of internal and external standardization.
URI: http://hdl.handle.net/10872/3926
ISSN: 0003-2700
Appears in Collections:Artículos Publicados

Files in This Item:

File Description SizeFormat
Laser ablation mass removal versus incident power density during solid sampling for inductively coupled plasma atomic emission spectroscopy.pdf380.76 kBAdobe PDFView/Open
View Statistics

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.