Please use this identifier to cite or link to this item:
https://saber.ucv.ve/jspui/handle/10872/30779Full metadata record
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Martínez Miletic, Carol Andrea | - |
| dc.contributor.author | Navas Zabaleta, Ismar Carolina | - |
| dc.date.accessioned | 2026-11-25T17:52:44Z | - |
| dc.date.available | 2026-11-25T17:52:44Z | - |
| dc.date.issued | 2019-12-12 | - |
| dc.identifier.uri | https://saber.ucv.ve/jspui/handle/10872/30779 | - |
| dc.description | Universidad Central de Venezuela, Facultad de Medicina, Coordinación de Estudios de Postgrado; Maternidad Concepción Palacios. Trabajo Especial de Grado que se Presenta para Optar al Título de Especialista en Obstetricia y Ginecología | en_US |
| dc.description.abstract | Objetivos: Determinar la utilidad de la medición ecográfica del espesor de las membranas corioamnióticas como predictor de riesgo para rotura prematura de membranas, en pacientes que acuden a Sala de Partos de la Maternidad Concepción Palacios, entre mayo y julio de 2019. Métodos: Estudio prospectivo, descriptivo, transversal. Incluyó 100 gestantes a término, con factores de riesgo para rotura prematura de membranas. Se midió el espesor de las membranas corioamnióticas por ecografía transabdominal. Resultados: El espesor medio fue 2,12 mm (1–4,4). A las 37 semanas, fue 1,8 mm, a las 40, 2,3 mm y a las 41 fue 1,9 mm (p=0,755). En pacientes con rotura prematura de membranas fue 2,0 mm (1,2–3), con rotura espontánea durante el trabajo de parto, 2,2 mm (2,1-3,9), con amniorrexis durante el trabajo de parto 2,1 mm (1–4,4) y durante la cesárea, 2,2 mm (1–4,4) (p=0,818). En ausencia de factores de riesgo, la media fue 2,8 ± 1,1 mm, con un factor de riesgo, 2,0 ± 0,5 mm y con 2 o más factores de riesgo, 2,1 ± 0,7 (p=0,042). Nueve pacientes con rotura prematura de membranas (60 %) tenían un espesor entre 1 mm y 2 mm. Ninguna paciente con más de 3 mm presentó rotura prematura de membranas. Con un punto crítico para rotura prematura de membranas de 1,85 mm, la sensibilidad fue 53,3 % y la especificidad 56,5 %. Conclusión: La medición ecográfica del espesor de las membranas corioamnióticas, no resultó eficaz como predictor de rotura prematura de membranas. Objectives: To determine the usefulness of the ultrasound measurement of the thickness of the corioamniotic membranes as a risk predictor for premature rupture of membranes, in patients who come to the Delivery Room of Maternidad Concepción Palacios, between May and July 2019. Methods: Prospective, descriptive, cross-sectional study, which included 100 full-term pregnant women with risk factors for premature membrane rupture. Transabdominal ultrasound was performed to measure the thickness of the corioamniotic membranes. Results: The average thickness was 2.12 mm (1–4.4). At 37 weeks, it was 1.8 mm, at 40, 2.3 mm and at 41 mm it was 1.9 mm (p=0.755). In patients with premature membrane rupture was 2.0 mm (1.2–3), with spontaneous rupture during labor, it was 2.2 mm (2.1-3.9), with amniorrexis during labor was 2.1 mm (1–4.4) and during C-section, it was 2.2 mm (1–4.4) (p=0.818). In the absence of risk factors, the mean was 2.8 x 1.1 mm, with 1 risk factor, 2.0 x 0.5 mm and with 2 or more risk factors, 2.1 x 0.7 (p-0.042). Nine patients with premature membrane rupture (60%) were between 1 mm and 2 mm thick. No patient with more than 3 mm had premature membrane rupture. With a critical point for premature membrane rupture of 1.85 mm, the sensitivity was 53.3% and specificity was 56.5%. Conclusion: The ultrasound measurement of the thickness of the corioamniotic membranes, was not effective as a predictor of premature rupture of membranes | en_US |
| dc.language.iso | es | en_US |
| dc.subject | Membranas Corioamnióticas | en_US |
| dc.subject | Rotura Prematura de Membranas | en_US |
| dc.subject | Espesor | en_US |
| dc.subject | Medición Ecográfica | en_US |
| dc.subject | Predictor | en_US |
| dc.subject | Obstetricia y Ginecología | en_US |
| dc.subject | Facultad de Medicina-UCV | en_US |
| dc.subject | Trabajo Especial de Grado | en_US |
| dc.subject | Chorioamniotic Membranes | en_US |
| dc.subject | Premature Rupture of Membranes | en_US |
| dc.subject | Thickness | en_US |
| dc.subject | Echographic Measurement | en_US |
| dc.subject | Predictor | en_US |
| dc.title | Rotura Prematura de Membranas: Medición Ecográfica del Espesor de las Membranas Corioamnióticas como Predictor de Riesgo | en_US |
| dc.type | Thesis | en_US |
| Appears in Collections: | Otras (Especializaciones) | |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| TEG Rotura prematura de membranas.pdf | 1.66 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.