Please use this identifier to cite or link to this item: https://saber.ucv.ve/jspui/handle/10872/24428
Full metadata record
DC FieldValueLanguage
dc.contributor.authorCelis Vargas, Viviana Isabel-
dc.contributor.authorRamos Vivas, Amaly Zwei-
dc.date.accessioned2026-06-02T17:31:18Z-
dc.date.available2026-06-02T17:31:18Z-
dc.date.issued2017-12-08-
dc.identifier.urihttps://saber.ucv.ve/jspui/handle/10872/24428-
dc.descriptionUniversidad Central de Venezuela, Facultad de Medicina, Coordinación de Estudios de Postgrado. Hospital Militar “Dr. Carlos Arvelo”, Trabajo Especial de Grado que se Presenta para Optar al Título de Especialista en Anestesiologíaen_US
dc.description.abstractObjetivo: Comparar la respuesta hemodinámica en pacientes hipertensos sometidos a cirugía electiva realizando intubación orotraqueal con laringoscopia directa versus intubación a través de máscara laríngea AMBU®. Métodos: Se realizó un estudio de tipo prospectivo, descriptivo, unicéntrico, de corte transversal. Resultados: Ambos grupos registraron cifras de tensión arterial y frecuencia cardiaca similares, sin embargo, se evidencio una tendencia al aumento de las mismas en el grupo AMBU®, contradictorio a lo esperado. Conclusiones: La intubación a través de la máscara laríngea AMBU® no demostró reducir efectivamente la respuesta hemodinámica en pacientes con HTA. Objective: To compare the hemodynamic response in hypertensive patients undergoing elective surgery by performing orotracheal intubation with direct laryngoscopy versus intubation through AMBU® laryngeal mask. Methods: A prospective, descriptive, unicentric, cross-sectional study was conducted. Results: Both groups showed similar blood pressure and heart rate, however, a tendency to increase them was observed in the AMBU® group, contradictory to what was expected. Conclusions: The intubation through the AMBU® laryngeal mask did not prove to effectively reduce the hemodynamic response in patients with hypertensionen_US
dc.description.sponsorship,en_US
dc.language.isoesen_US
dc.subjectMáscara laríngea AMBU®en_US
dc.subjectlaringoscopia directaen_US
dc.subjecthipertensión arterialen_US
dc.subjectrespuesta hemodinámicaen_US
dc.subjectAMBU® laryngeal masken_US
dc.subjectdirect laryngoscopyen_US
dc.subjectarterial hypertensionen_US
dc.subjecthemodynamic responseen_US
dc.subjectTrabajo de Gradoen_US
dc.subjectFacultad de Medicinaen_US
dc.subjectAnestesiologíaen_US
dc.titleIntubacion Orotraqueal bajo Laringoscopia Directa vs Intubacion con Mascara Ambu®: Evaluacion de la Respuesta Hemodinamica en Pacientes Hipertensosen_US
dc.typeThesisen_US
Appears in Collections:Otras (Especializaciones)

Files in This Item:
File Description SizeFormat 
Celis Viviana Ramos Amaly_Finalpublicacion.pdf1.05 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.