Title: Compliance Estático - Dinámico Y Co2 en Pacientes Sometidos a Ventilación Unipulmonar, para Resección Pulmonar en Ventilación modo Volumen Versus modo Presión
Authors: Gámez Molina, Frank Enrique
Merchán Penoth, Angela Carolina
Keywords: Resección pulmonar
ventilación modo volumen
ventilación modo presión
ventilación unipulmonar
compliance estático
compliance dinámico
CO2 tele-espirado
presión arterial de CO2
pulmonary resection
volume ventilation mode
ventilation pressure mode
one lung ventilation
static compliance
dynamic compliance
tele-tidal CO2
blood pressure of CO2
Issue Date: Jun-2012
Abstract: Objetivo: Seleccionar el modo ventilatorio, que minimice el potencial daño asociado a ventilación mecánica con ventilación unipulmonar en cirugía torácica para resección pulmonar. Método: se realizó un estudio analítico, comparativo, con muestra de 20 pacientes ASA I y ASA II, del servicio de Cirugía de tórax del HUC, edad 22-60 años, sometidos a resección pulmonar, bajo ventilación unipulmonar. 10 iniciados en ventilación modo presión y 10 en modo volumen, se monitoreó el ETCO2, compliance estático y dinámico. Resultados: se encontró un mejor desempeño en la ventilación modo presión, con un manejo del ETCO2 (p=0.010) y compliance estático (p=0.015) y dinámico (p=0.023) más adecuado. 70% de los pacientes iniciados en modo volumen, requirieron cambio a modo presión. Conclusión: el mejor modo ventilatorio para los pacientes sometidos a resección pulmonar, bajo aislamiento pulmonar, es el modo presión, mostrando mejor desempeño ventilatorio. Objective: Select the ventilator mode that minimizes the potential damage associated with mechanical ventilation with one-lung ventilation in thoracic surgery for lung resection. Method: An analytical study, comparative sample of 20 patients with ASA I and ASA II of Chest Surgery Service of the HUC, age 22-60 years, who underwent lung resection one lung ventilation. 10 started in ventilation pressure mode and 10 mode volumes, ETCO2 was monitored, static and dynamic compliance. Results: We found better performance in ventilation pressure mode, with a management ETCO2 (p = 0.010) and static compliance (p = 0.015) and dynamic (p = 0.023) more appropriate. 70% of patients started in volume mode required as a pressure change. Conclusion: The best way to ventilator patients undergoing lung resection, low lung isolation is the pressure mode, showing better performance ventilation.
Description: Universidad Central de Venezuela, Facultad de Medicina, Comisión de Estudios de Postgrado. Hospital Universitaria de Caracas. Trabajo Especial de Grado que se presenta para optar al título de Especialista en Anestesiología
URI: https://saber.ucv.ve/handle/10872/24226
Appears in Collections:Otras

Files in This Item:

File Description SizeFormat
CERTIFICACION DEL TUTOR Y VEREDICTOS.PDF2.1 MBAdobe PDFView/Open
TESIS COMPLIANCE ESTÁTICO - DINÁMICO Y CO2 EN PACIENTES SOMETIDOS A VENTILACION UNIPULMONA.pdf853.18 kBAdobe PDFView/Open

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2010  Duraspace - Feedback