dc.identifier.citationFernández Paredes, Luciana De Jesús; Pineda Chávez, Adriana Isabel (2021). Anticoncecepción Prolongada y reversible. Efectividad del anclaje del dipositivomintrauterino t de cobre 380 a, Transcesarea segmentaria para reducir la frecuencia de su expulsión.Trabajo Especial de Grado que se presenta para optar al título de Especialista en Obstetricia y Ginecología en la Facultad de Medicina de la UCV. Tutor: Esp. Galiano, joséen_US
dc.identifier.urihttp://hdl.handle.net/10872/22054-
dc.description.abstractDeterminar la efectividad de la técnica de anclaje del DIU T de cobre 380 A para reducir la tasa de expulsión del dispositivo insertado transcesárea, en pacientes que ingresaron al servicio de obstetricia del IVSS Hospital “Dr. Miguel Pérez Carreño”, en el periodo julio 2019 – julio 2020. Métodos: Estudio prospectivo, comparativo, longitudinal, aleatorizado. Se incluirán 80 pacientes con indicación de cesárea segmentaria y deseo de anticoncepción con dispositivo intrauterino. Se trabajará con dos grupos y en ambos se insertará el dispositivo a cada paciente inmediatamente después del alumbramiento. En el grupo A por técnica manual habitual y en el grupo B se practicará el anclaje con un punto simple a nivel de fondo uterino con crómico, fijando el dispositivo a nivel del inicio del brazo vertical en su porción plástica. Se realizará ecografía de control a los días 7 y 42 del posoperatorio. Se comparará la frecuencia de expulsión y los factores involucradosen_US
dc.description.sponsorshipEvaluate the effectiveness of the 380 A copper IUD T anchoring technique to reduce the expulsion rate of the transcessarea inserted device, in patients who entered the obstetrics service of IVSS Hospital "Dr. Miguel Pérez Carreño", in the period July 2019 – July 2020. Methods: Prospective, comparative, longitudinal, randomized study. 80 patients with indication of segmental C-section and desire for contraception with intrauterine device shall be included. Both devices will be inserted immediately after delivery. In group A by usual manual technique and in group B the anchoring will be practiced with a simple point at the uterine background level with chromosome, fixing the device at the level of the start of the vertical arm in its plastic part. Control ultrasound will be performed on days 7 and 42 of the postoperative period. The frequency of expulsion and the factors involved will be compareden_US
dc.language.isoesen_US
dc.subjectDispositivo intrauterinoen_US
dc.subjectMétodo anticonceptivoen_US
dc.subjectCesárea segmentariaen_US
dc.subjectFaculta de Medicinaen_US
dc.subjectHospital Miguel Perez Carreñoen_US
dc.titleAnticoncecepción Prolongada y reversible. Efectividad del anclaje del dipositivomintrauterino t de cobre 380 a, Transcesarea segmentaria para reducir la frecuencia de su expulsiónen_US
dc.typeThesisen_US
Appears in Collections:Otras (Especializaciones)

Files in This Item:
File Description SizeFormat 
lucianafernandez_archivofinal.pdf2.15 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.