> Aerosol diagnostics and inductively coupled plasma mass spectrometry with demountable concentric nebulizers
Please use this identifier to cite or link to this item: https://saber.ucv.ve/handle/10872/14411

Title: Aerosol diagnostics and inductively coupled plasma mass spectrometry with demountable concentric nebulizers
Authors: Ann E., Su-
Murdock, O’Brien
Kahen, Kaveh
Chirinos, José
Ketterer, Michael E.
Hudson, David D.
Montaser, Akbar
Issue Date: 2004
Series/Report no.: Nº 5
Abstract: A demountable concentric nebulizer (DCN) is evaluated for inductively coupled plasma mass spectrometry (ICPMS). This nebulizer operates at conditions similar to a commercial pneumatic nebulizer used in ICP spectrometries, but is easily fabricated and is considerably less expensive. Key aerosol diagnostics data, and analytical figures of merit are presented for the DCN used in ICPMS. The DCN produces a better quality primary aerosol when using inner capillaries of smaller diameters. At a solution uptake rate of about 500 mL min21 and a nebulizer gas flow rate of 1.0 L min21, the Sauter mean diameter (D3,2) of the primary aerosol of the DCN is 7 mm and 14 mm for solution capillaries having an i.d. of 95 mm (DCN-1) and 190 mm (DCN-2), respectively. Based on the cumulative mass percent data, nearly 70% of the total mass of the droplets produced by DCN-1, under the above conditions, is composed of droplets having sizes less than 10 mm. The D3,2 of the tertiary aerosol of DCN-1, under the same operating conditions, is reduced to 5 and 3 mm when the nebulizer is coupled to a Scott-type and a cyclonic spray chamber, respectively. The tertiary aerosol of the DCNs studied does not show substantially different D3,2 values, particularly when the cyclonic spray chamber is used. Under optimum conditions, detection limits, sensitivities, and precision for the DCN compare favorably with a commercially available crossflow nebulizer. The accuracy and precision of the DCN in ICPMS measurements are demonstrated using two standard reference materials: SRM 1643c (Trace Elements in Water), and SRM 1570 (Trace Elements in Spinach).
URI: http://hdl.handle.net/10872/14411
ISSN: 0267-9477
Appears in Collections:Artículos Publicados

Files in This Item:

File Description SizeFormat
Aerosol Diagnostic.pdf849.72 kBAdobe PDFView/Open
View Statistics

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.