|
SABER UCV >
2) Tesis >
Otras >
Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/10872/16401
|
Título : | Dispositivo intrauterino t de cobre 380a: seguridad como método anticonceptivo en estado post - aborto |
Otros títulos : | Intrauterine device t copper 380a: safety for contraception state post – abortion |
Autor : | González Pedriquez, Melitza Jasmin |
Palabras clave : | Anticoncepción DIU T de cobre 380A Estado post aborto Contraception IUDs T Copper 380A State post abortion |
Fecha de publicación : | 2017 |
Editorial : | UCV |
Citación : | 2017;1000-003 |
Resumen : | Determinar la seguridad del dispositivo intrauterino T de cobre 380A como anticonceptivo post - aborto en pacientes que acudieron a la Maternidad “Concepción Palacios” entre marzo 2015 – junio 2016. Métodos: Estudio prospectivo, longitudinal y descriptivo con una muestra no probabilística de 80 pacientes, se les insertó el dispositivo intrauterino durante las primeras 24 horas posteriores al vaciamiento uterino. Se realizó seguimiento con ultrasonido transvaginal, inmediato, a los 7 y 30 días y 3 meses después. Se evaluó la seguridad del método según la edad gestacional alcanzada y el método de evacuación uterina y la adherencia de las pacientes según la edad. Resultados: la edad promedio de las pacientes fue 27,3 ± 6,9 años, el diagnóstico de ingreso más frecuente fue aborto incompleto (37,5 %) con edad gestacional promedio alcanzada de 10,2 ± 3,9 semanas, el método de evacuación uterina fue legrado uterino en 60 % de los casos. La complicación más frecuente fue el sangrado entre las 5-9 semanas (31,8 %) y las 15-20 semanas (26,6%) (P= 0,104). Entre las 10–14 semanas se presentó dolor en 22,7 % de los casos (P= 0,956). Hubo 12 pacientes con dolor en aquellas a quienes se les realizó legrado uterino y 9 casos cuando se practicó aspiración manual endouterina (P=0,960). Hubo un embarazo y un caso de perforación uterina. La adherencia al método se presentó en un 90 % (72 pacientes). Conclusiones: El dispositivo intrauterino, T de cobre 380A, es seguro como anticonceptivo en estado post – aborto. |
Descripción : | To determine the safety of IUD Copper T 380A as a contraceptive in state post - abortion in patients attending the Maternity "Concepcion Palacios" in the period March 2015 - June 2016. Methods: A prospective study was conducted, longitudinal and descriptive with a non-probabilistic sample of 80 patients who were inserted intrauterine device during the first 24 hours after uterine emptying. The monitoring was performed with transvaginal ultrasound immediately, at 7 and 30 days and 3 months verifying the insertion and retention of the intrauterine device according sonographic parameters measuring the background distance uterus - intrauterine device (DFD: 20mm ± 5) and interrogation complications regarding each control. The safety of the method was evaluated by gestational age reached and method of
2
uterine evacuation, and adherence of patients to the contraceptive method according to the age of the same. Results: The mean age of patients was 27.3 ± 6.9 between years, the most frequent diagnosis of incomplete abortion income was 37.5% with a mean gestational age of 10.2 ± 3.9 reached weeks the main method of uterine evacuation curettage used was 60%. The most common complication between 5 -9 weeks 15 -20 weeks and was bleeding from moderate to abundant with 31.8% and 26.6% respectively of total presented complications (P = 0.104); between 10 to 14 weeks, the pain in 22.7% of these cases (P = 0.956) was introduced, there were 12 cases of patients with pain in those who were underwent curettage compared with 9 cases in manual vacuum aspiration (P = 0.960) were statistically not significant. There was a pregnancy, uterine perforation and uterine perforation. Adherence to the method presented in 90% (72 patients). Conclusions: The symptoms described by patients in IUD insertion in post abortion state seem to have no relevance when deciding adherence to method and is not appropriate to defer the inclusion of this when the complication rate is similar to those present in patients without abortion, thus offering a safe and effective contraceptive method immediately. |
URI : | http://hdl.handle.net/10872/16401 |
Aparece en las colecciones: | Otras
|
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.
|